Abdominal and Direct Fetal Electrocardiogram Database

The new PhysioNet website is available at: https://physionet.org. We welcome your feedback.

When referencing this material, please cite at least one of the following publications:

  1. Jezewski J, Matonia A, Kupka T, Roj D, Czabanski R. >Determination of the fetal heart rate from abdominal signals: evaluation of beat-to-beat accuracy in relation to the direct fetal electrocardiogram. Biomedical Engineering/Biomedizinische Technik 2012 Jul;57(5):383-394. doi:10.1515/bmt-2011-0130.
  2. Matonia A, Jezewski J, Kupka T, Horoba K, Wrobel J, Gacek A. The influence of coincidence of fetal and maternal QRS complexes on fetal heart rate reliability. Medical & Biological Engineering & Computing 2006;44(5):393-403.
  3. Kotas M, Jezewski J, Horoba L, Matonia A. Application of spatio-temporal filtering to fetal electrocardiogram enhancement. Computer Methods and Programs in Biomedicine. 2011 Oct;104(1):1-9.
  4. Kotas M, Jezewski J, Matonia A, Kupka T. Towards noise immune detection of fetal QRS complexes. Computer Methods and Programs in Biomedicine. 2010 Mar;97(3):241-256.

Please also include the standard citation for PhysioNet:

Goldberger AL, Amaral LAN, Glass L, Hausdorff JM, Ivanov PCh, Mark RG, Mietus JE, Moody GB, Peng C-K, Stanley HE. PhysioBank, PhysioToolkit, and PhysioNet: Components of a New Research Resource for Complex Physiologic Signals. Circulation 101(23):e215-e220 [Circulation Electronic Pages; http://circ.ahajournals.org/content/101/23/e215.full]; 2000 (June 13).

The research material included in the Abdominal and Direct Fetal Electrocardiogram Database contains multichannel fetal electrocardiogram (FECG) recordings obtained from 5 different women in labor, between 38 and 41 weeks of gestation. The recordings were acquired in the Department of Obstetrics at the Medical University of Silesia, by means of the KOMPOREL system for acquisition and analysis of fetal electrocardiogram (ITAM Institute, Zabrze, Poland). Each recording comprises four differential signals acquired from maternal abdomen and the reference direct fetal electrocardiogram registered from the fetal head.

The configuration of the abdominal electrodes comprised four electrodes placed around the navel, a reference electrode placed above the pubic symphysis and a common mode reference electrode (with active-ground signal) placed on the left leg. To reduce the skin impedance, the areas under the Ag-AgCl electrodes were abraded. In all cases, the scalp electrode was placed for a clinical indication and all women consented to participate in this study.

The acquisition of direct fetal electrocardiogram was carried out with a typical spiral electrode, commonly used in a direct FECG channel of popular fetal monitors. The R-wave locations were automatically determined in the direct FECG signal by means of on-line analysis applied in the KOMPOREL system. These locations were then verified (off-line) by a group of cardiologists, resulting in a set of reference markers precisely indicating the R-wave locations. The markers have been stored together with the direct and indirect FECG signals in EDF/EDF+ format.

The provided recordings constitute an excellent material for testing and evaluation of efficacy of new FECG processing techniques, e.g. algorithms for suppression of maternal electrocardiogram in abdominal signals or for detection of fetal QRS complexes. In the authors' studies (1-4 above), these recordings were used to evaluate the accuracy of fetal heart rate measurement and to estimate its influence on the quantification of the beat-to-beat fetal heart rate (FHR) variability.

Recording information:

Icon  Name                    Last modified      Size  Description
[PARENTDIR] Parent Directory - [   ] DOI 2019-02-01 16:16 19 [   ] ANNOTATORS 2012-08-06 19:43 30 list of annotators [   ] RECORDS 2012-12-12 11:35 40 list of record names [   ] MD5SUMS 2012-12-12 11:36 574 [   ] SHA1SUMS 2012-12-12 11:36 678 [   ] SHA256SUMS 2012-12-12 11:36 1.0K [   ] r07.edf.qrs 2012-08-02 06:15 1.3K verified beat annotations [   ] r04.edf.qrs 2012-08-02 06:15 1.3K verified beat annotations [   ] r01.edf.qrs 2012-08-02 06:14 1.3K verified beat annotations [   ] r10.edf.qrs 2012-08-02 06:16 1.3K verified beat annotations [   ] r08.edf.qrs 2012-08-02 06:16 1.3K verified beat annotations [   ] r01.edf 2012-08-02 06:14 2.9M digitized signals [   ] r04.edf 2012-08-02 06:15 2.9M digitized signals [   ] r07.edf 2012-08-02 06:15 2.9M digitized signals [   ] r08.edf 2012-08-02 06:15 2.9M digitized signals [   ] r10.edf 2012-08-02 06:16 2.9M digitized signals

Questions and Comments

If you would like help understanding, using, or downloading content, please see our Frequently Asked Questions.

If you have any comments, feedback, or particular questions regarding this page, please send them to the webmaster.

Comments and issues can also be raised on PhysioNet's GitHub page.

Updated Friday, 28 October 2016 at 16:58 EDT

PhysioNet is supported by the National Institute of General Medical Sciences (NIGMS) and the National Institute of Biomedical Imaging and Bioengineering (NIBIB) under NIH grant number 2R01GM104987-09.