mgh177 8 360/0.476 1490400 14:57:27 10/10/1992 mgh177.dat 212 400 12 0 453 -24021 0 ECG lead I mgh177.dat 212 400 12 0 51 25129 0 ECG lead II mgh177.dat 212 400 12 0 86 18693 0 ECG lead V mgh177.dat 212 11.82(-1610)/mmHg 12 0 51 -10988 0 ART mgh177.dat 212 18.04(-1463)/mmHg 12 0 -929 29559 0 PAP mgh177.dat 212 20.2(-1398)/mmHg 12 0 -957 -6002 0 CVP mgh177.dat 212 1000 12 0 99 14522 0 Resp. Imp. mgh177.dat 212 1000 12 0 1118 27173 0 CO2 #: 67 : F : Abdominal aortlc aneurysm; Aorto-bifemoral graft; Aorto-iliac occlusion; Bilateral lumbar sympathectomy # ELECTROCARDIOGRAPHIC DATA: # UNDERLYING RHYTHM: # Normal sinus rhythm @ 84 bpm # RHYTHM DISTURBANCES: # Rare multifocal ventricular ectopy # ECG INTERPRETATION: # Nonspecific T wave abnormalities # TECHNICAL COMMENTS: # Occasional artifact from muscle tremor # HEMODYNAMIC DATA: # ART: 140/60 MEAN: 84 # PAP: 28/14 PCW: 8 (@ 24 min, 39 min, 52 min) # RAP: 8 # WAVEFORM PATTERNS: # Respiratory variation # RESPIRATORY DATA: # RATE: 16 bpm # MODE OF VENTILATION: # Spontaneous