sigamp - measure signal amplitudes of a WFDB record 
sigamp -r
record [ options ... ] 
sigamp measures either baseline-corrected
RMS amplitudes or (for suitably annotated ECG signals) normal QRS peak-to-peak
amplitudes for all signals of the specified record.  It makes up to 300
measurements (but see -n below) for each signal and calculates trimmed means
(by discarding the largest and smallest 5% of the measurements and taking
the mean of the remaining 90%). 
Options include: 
- -a annotator 
- Measure QRS
peak-to-peak amplitudes based on normal QRS annotations from the specified
annotator. 
- -d dt1 dt2 
- Set the measurement window relative to QRS annotations.
 Defaults: dt1 = 0.05 (seconds before the annotation);  dt2 = 0.05 (seconds
after the annotation). 
- -f time 
- Begin at the specified time in record (default:
the beginning of record). 
- -h 
- Print a usage summary. 
- -H 
- Read the signal files
in high-resolution mode (default: standard mode). These modes are identical
for ordinary records.  For multifrequency records, the standard decimation
of oversampled signals to the frame rate is suppressed in high-resolution
mode (rather, all other signals are resampled at the highest sampling frequency).
- -n nmax 
- Make up to nmax measurements on each signal (default: 300). 
- -p 
- Print
results in physical units (default: ADC units). -p may be followed by a single
character to specifify a time format (used with -q and -v when printing individual
measurements); choices are -pd (time of day and date if known), -pe (elapsed
time in hours, minutes, and seconds), -ph (elapsed time in hours), -pm (elapsed
time in minutes), -ps (elapsed time in seconds (default)), -pS (elapsed time
in sample intervals). 
- -q 
- Quick mode: print individual measurements only. 
- -t
time 
- Process until the specified time in record (default: the end of the
record).  Processing will be terminated prematurely if 250 measurements
are made before reaching the specified time. 
- -v 
- Verbose mode: print individual
measurements as well as trimmed means. 
- -w dtw 
- Set RMS amplitude measurement
window.  Default: dtw = 1 (second). 
It may be necessary to set
and export the shell variable WFDB (see setwfdb(1)
). 
calsig(1)
,
setwfdb(1)
, sigavg(1)
 
George B. Moody (george@mit.edu) 
http://www.physionet.org/physiotools/wfdb/app/sigamp.c