The data set and its collection methods are described in
A support PDF showing the lead placement is also provided.
When referencing this material, please include the citation above, and also include the standard citation for PhysioNet:
Short duration ECG signals are recorded from a healthy 25-year-old male performing different physical activities to study the effect of motion artifacts on ECG signals and their sparsity.
For each measurement, 4 pairs of electrodes built into a single patch are placed on the subject. The electrodes are arranged at 45-degree offsets as shown below:
The patch itself is also placed at multiple orientations relative to the body:
Each recording contains four signals (ECG 1
to ECG 4
) corresponding to the four pairs of electrodes.
Recording information:
- Sampling rate: 500 Hz
- Resolution: 16 bits
- An analogue gain of 100 is applied to the raw ECG recordings before ADC.
- The 2-digit number before the last letter shows the offset of the whole electrode patch in degrees.
- The last letter of each record name corresponds to the type of physical activity as below:
- s = standing
- w = walking
- j = single jump
Name Last modified Size Description
Parent Directory - test01_00s.dat 2015-11-17 17:52 31K digitized signal(s) test02_45s.dat 2015-11-17 17:52 31K digitized signal(s) test03_90s.dat 2015-11-17 17:52 31K digitized signal(s) test04_00s.dat 2015-11-17 17:52 31K digitized signal(s) test05_45s.dat 2015-11-17 17:52 31K digitized signal(s) test06_90s.dat 2015-11-17 17:52 31K digitized signal(s) test07_00s.dat 2015-11-17 17:52 31K digitized signal(s) test08_45s.dat 2015-11-17 17:52 31K digitized signal(s) test09_90s.dat 2015-11-17 17:52 31K digitized signal(s) test10_00w.dat 2015-11-17 17:52 31K digitized signal(s) test11_45w.dat 2015-11-17 17:52 31K digitized signal(s) test12_90w.dat 2015-11-17 17:52 31K digitized signal(s) test13_00w.dat 2015-11-17 17:52 31K digitized signal(s) test14_45w.dat 2015-11-17 17:52 31K digitized signal(s) test15_90w.dat 2015-11-17 17:52 31K digitized signal(s) test16_00w.dat 2015-11-17 17:52 31K digitized signal(s) test17_45w.dat 2015-11-17 17:52 31K digitized signal(s) test18_90w.dat 2015-11-17 17:52 31K digitized signal(s) test19_00j.dat 2015-11-17 17:52 31K digitized signal(s) test20_45j.dat 2015-11-17 17:52 31K digitized signal(s) test21_90j.dat 2015-11-17 17:52 31K digitized signal(s) test22_00j.dat 2015-11-17 17:52 31K digitized signal(s) test23_45j.dat 2015-11-17 17:52 31K digitized signal(s) test24_90j.dat 2015-11-17 17:52 31K digitized signal(s) test25_00j.dat 2015-11-17 17:52 31K digitized signal(s) test26_45j.dat 2015-11-17 17:52 31K digitized signal(s) test27_90j.dat 2015-11-17 17:52 31K digitized signal(s) electrode_patch.pdf 2015-11-25 15:24 129K test01_00s.hea 2015-12-16 18:01 277 header file test02_45s.hea 2015-12-16 18:01 276 header file test03_90s.hea 2015-12-16 18:01 274 header file test04_00s.hea 2015-12-16 18:01 275 header file test05_45s.hea 2015-12-16 18:01 271 header file test06_90s.hea 2015-12-16 18:01 272 header file test07_00s.hea 2015-12-16 18:01 271 header file test08_45s.hea 2015-12-16 18:01 274 header file test09_90s.hea 2015-12-16 18:01 273 header file test10_00w.hea 2015-12-16 18:01 272 header file test11_45w.hea 2015-12-16 18:01 275 header file test12_90w.hea 2015-12-16 18:01 277 header file test13_00w.hea 2015-12-16 18:01 275 header file test14_45w.hea 2015-12-16 18:01 271 header file test15_90w.hea 2015-12-16 18:01 272 header file test16_00w.hea 2015-12-16 18:01 274 header file test17_45w.hea 2015-12-16 18:01 274 header file test18_90w.hea 2015-12-16 18:01 273 header file test19_00j.hea 2015-12-16 18:01 277 header file test20_45j.hea 2015-12-16 18:01 278 header file test21_90j.hea 2015-12-16 18:01 277 header file test22_00j.hea 2015-12-16 18:01 273 header file test23_45j.hea 2015-12-16 18:01 275 header file test24_90j.hea 2015-12-16 18:01 269 header file test25_00j.hea 2015-12-16 18:01 276 header file test26_45j.hea 2015-12-16 18:01 273 header file test27_90j.hea 2015-12-16 18:01 274 header file RECORDS 2015-12-16 18:03 297 list of record names patch_electrodes.jpg 2015-12-16 18:17 15K patch_location.png 2015-12-16 18:17 36K MD5SUMS 2015-12-18 15:10 2.9K SHA1SUMS 2015-12-18 15:10 3.3K SHA256SUMS 2015-12-18 15:10 4.7K DOI 2016-02-18 10:48 20
If you would like help understanding, using, or downloading content, please see our Frequently Asked Questions. If you have any comments, feedback, or particular questions regarding this page, please send them to the webmaster. Comments and issues can also be raised on PhysioNet's GitHub page. Updated Friday, 28 October 2016 at 16:58 EDT |