Version 1 - September 2017
When referencing this material, please cite:
@article{pmd, author = {M. Baran Pouyan, J. Birjandtalab, M. Heydarzadeh, M. Nourani, and S. Ostadabbas}, title = {A pressure map dataset for posture and subject analytics}, journal = {IEEE EMBS International Conference on Biomedical & Health Informatics (BHI)}, year = {2017} }
Please also include the standard citation for PhysioNet:
@article{PhysioNet, author = {Goldberger, Ary L. and Amaral, Luis A. N. and Glass, Leon and Hausdorff, Jeffrey M. and Ivanov, Plamen Ch. and Mark, Roger G. and Mietus, Joseph E. and Moody, George B. and Peng, Chung-Kang and Stanley, H. Eugene}, title = {{PhysioBank}, {PhysioToolkit}, and {PhysioNet}: Components of a New Research Resource for Complex Physiologic Signals}, journal = {Circulation}, publisher = {American Heart Association, Inc.}, volume = {101}, number = {23}, year = {2000}, month = {June}, pages = {e215--e220}, doi = {10.1161/01.CIR.101.23.e215}, issn = {0009-7322}, url = {http://circ.ahajournals.org/content/101/23/e215} }
Data Collection
In this project, we collected in-bed posture pressure data from multiple adult participants using two different types of pressure sensing mats. To the best of our knowledge, our dataset, PmatData is the first publicly-available dataset of pressure sensor data which includes various sleeping postures. PmatData contains pressure data from two separate experiments. These two experiments are:
- Experiment I: Pressure data from 13 participants in 8 standard postures and 9 additional states.
- Data is collected using Vista Medical FSA SoftFlex 2048
- Size of pressure mat is 32*64. This is the raw data collected reporting numbers in range of [0-1000] for each sensor.
- Sampling rate is 1Hz.
- Each file includes the data frames around 2-mins (around 120 frames).
- Experiment II: pressure data from 8 participants in 29 different states of 3 standard postures. Furthermore, experiment II was collected separately for both regular and air-alternating pressure mattresses.
- Data is collected using Vista Medical BodiTrak BT3510
- Size of pressure mat is 27*64. This is the raw data collected reporting numbers in range of [0-500] for each sensor.
- Sampling rate is 1Hz.
- Each file contains the average of around 20 frames.
- The data is collected for both sponge and air mattresses separately.
Data Files
The experiment-info.docx
file provides information about subjects and postures, including visual diagrams. There are also subject-info-*.csv
files in each experiment subdirectory describing subject information.
The data files are provided in tab delimited text format, listed in subdirectories named after the experiment number and subject number.
For experiment i, the text files are named after the position number from 1-17. Each file contains multiple frames of recordings, with the 2048 columns representing the 32x64 pressure sensor measurements, and each row giving a new set of samples.
For experiment ii, the text files are named after the 29 position numbers. Each file contains one average of multiple frames of recordings. In contrast with the experiment i text files, the 27 columns and 64 rows represent the 27x64 sensor matrix.
Contributors
A team of researchers from Quality of Life Technology (QoLT) Laboratory at the University of Texas at Dallas created and contributed this database to PhysioNet. The contributors include Maziyar Baran Pouyan, Javad Birjandtalab, Mehrdad Heydarzadeh, Sarah Ostadabbas, Rasoul Yousefi, Masoud Farshbaf and Mehrdad Nourani (Faculty Advisor) and Matthew Pompeo, MD (clinical consultant).
Name Last modified Size Description
Parent Directory -
experiment-i/ 2017-09-27 14:41 -
experiment-ii/ 2017-09-27 14:41 -
experiment-info.docx 2017-09-27 14:52 534K
DOI 2019-02-19 14:20 19
If you would like help understanding, using, or downloading content, please see our Frequently Asked Questions. If you have any comments, feedback, or particular questions regarding this page, please send them to the webmaster. Comments and issues can also be raised on PhysioNet's GitHub page. Updated Friday, 28 October 2016 at 16:58 EDT |
PhysioNet is supported by the National Institute of General Medical Sciences (NIGMS) and the National Institute of Biomedical Imaging and Bioengineering (NIBIB) under NIH grant number 2R01GM104987-09.
|