Unconstrained and Metronomic Walking
Fractal dynamics were recently detected in the apparently “noisy” variations in the stride interval of human walking. Dynamical analysis of these step-to-step fluctuations revealed a self-similar pattern: fluctuations at one time scale are statistically similar to those at multiple other time scales, at least over hundreds of steps, while healthy subjects walk at their normal rate. To study the stability of this fractal property, we analyzed data obtained from ten healthy subjects who walked for 1 hour at their usual, slow and fast paces. The stride interval fluctuations exhibited long-range correlations with power-law decay for up to a thousand strides at all three walking rates. In contrast, during metronomically-paced walking, these long-range correlations disappeared; variations in the stride interval were anti-correlated. The long-range correlations observed during spontaneous walking were not affected by removal of drifts in the time series. Thus, the fractal dynamics of spontaneous stride interval are normally quite robust and intrinsic to the locomotor system. Furthermore, this fractal property of neural output may be related to the higher nervous centers responsible for control of walking rhythm.
Stride interval fluctuations were studied in ten young, healthy men. Participants had no history of any neuromuscular, respiratory or cardiovascular disorders, and were taking no medications. Mean age was 21.7 years (range: 18-29 years). Height was 1.77 ± 0.08 meters (mean ± S.D.) and weight was 71.8 ± 10.7 kg. All subjects provided informed written consent.
Subjects walked continuously on level ground around an obstacle free, long (either 225 or 400 meters), approximately oval path and the stride interval was measured using ultra-thin, force sensitive switches taped inside one shoe. For more details, please see the accompanying publication.
Each subject was given an arbitrary id (si01, si02, ... si10). For each subject, there are six data files: normal (.norm), slow (.slow) and fast (.fast) walking for 1 hour each as well as walking in time to a metronome at normal (.metnrm), slow (.metslw) and fast (.metfst) paces.
We find robust long-range correlations during unconstrained walking at all three walking rates and anti-correlations during metronomic walking. What do you find? Are there other rate or condition dependent effects on the histogram or the dynamics?
For more information, please see:
or contact Jeff Hausdorff.
Name Last modified Size Description
Parent Directory - si10.slow 2001-01-17 18:47 15K si10.norm 2001-01-17 18:47 17K si10.metslw 2001-01-17 18:47 8.1K si10.metnrm 2001-01-17 18:47 9.0K si10.metfst 2001-01-17 18:47 9.4K si10.fast 2001-01-17 18:47 19K si09.slow 2001-01-17 18:47 16K si09.norm 2001-01-17 18:47 18K si09.metslw 2001-01-17 18:47 8.3K si09.metnrm 2001-01-17 18:47 9.2K si09.metfst 2001-01-17 18:47 9.9K si09.fast 2001-01-17 18:47 20K si08.slow 2001-01-17 18:47 12K si08.norm 2001-01-17 18:47 17K si08.metslw 2001-01-17 18:47 7.1K si08.metnrm 2001-01-17 18:47 8.4K si08.metfst 2001-01-17 18:47 10K si08.fast 2001-01-17 18:47 22K si07.slow 2001-01-17 18:47 16K si07.norm 2001-01-17 18:47 17K si07.metslw 2001-01-17 18:47 8.3K si07.metnrm 2001-01-17 18:47 10K si07.metfst 2001-01-17 18:47 10K si07.fast 2001-01-17 18:47 20K si06.slow 2001-01-17 18:47 17K si06.norm 2001-01-17 18:47 19K si06.metslw 2001-01-17 18:47 10K si06.metnrm 2001-01-17 18:47 9.6K si06.metfst 2001-01-17 18:47 8.4K si06.fast 2001-01-17 18:47 20K si05.slow 2001-01-17 18:47 15K si05.norm 2001-01-17 18:47 20K si05.metslw 2001-01-17 18:47 7.7K si05.metnrm 2001-01-17 18:47 9.3K si05.metfst 2001-01-17 18:47 11K si05.fast 2001-01-17 18:47 22K si04.slow 2001-01-17 18:47 15K si04.norm 2001-01-17 18:47 18K si04.metslw 2001-01-17 18:47 8.3K si04.metnrm 2001-01-17 18:47 10K si04.metfst 2001-01-17 18:47 11K si04.fast 2001-01-17 18:47 21K si03.slow 2001-01-17 18:47 21K si03.norm 2001-01-17 18:47 20K si03.metslw 2001-01-17 18:47 8.0K si03.metnrm 2001-01-17 18:47 9.7K si03.metfst 2001-01-17 18:47 11K si03.fast 2001-01-17 18:47 19K si02.slow 2001-01-17 18:47 20K si02.norm 2001-01-17 18:47 20K si02.metslw 2001-01-17 18:47 10K si02.metnrm 2001-01-17 18:47 11K si02.metfst 2001-01-17 18:47 10K si02.fast 2001-01-17 18:47 22K si01.slow 2001-01-17 18:47 19K si01.norm 2001-01-17 18:47 20K si01.metslw 2001-01-17 18:47 8.8K si01.metnrm 2001-01-17 18:47 9.7K si01.metfst 2001-01-17 18:47 11K si01.fast 2001-01-17 18:47 21K fig.ps 2001-08-16 14:33 281K fig.png 2001-08-16 14:35 37K SHA256SUMS 2007-09-18 12:40 4.9K SHA1SUMS 2005-07-13 02:27 3.3K MD5SUMS 2005-07-13 02:27 2.8K DOI 2019-02-19 13:53 19
If you would like help understanding, using, or downloading content, please see our Frequently Asked Questions. If you have any comments, feedback, or particular questions regarding this page, please send them to the webmaster. Comments and issues can also be raised on PhysioNet's GitHub page. Updated Friday, 28 October 2016 at 16:58 EDT |
PhysioNet is supported by the National Institute of General Medical Sciences (NIGMS) and the National Institute of Biomedical Imaging and Bioengineering (NIBIB) under NIH grant number 2R01GM104987-09.
|